Warnings (W codes)

W001, W002Sun low

Not enough voltage from the panels to switch on or stay on. Normal outside the brighter part of the day.

Safe to reset?
Safe to restart
When to call an engineer
Only a concern in good light at midday.

W003Grid parameters out of range

The grid voltage or frequency is outside the limits set at installation.

Safe to reset?
Safe to restart
When to call an engineer
If it repeats, ask your DNO to check the supply.

W004, W005Grid voltage too high or too low

The grid voltage is above or below the set limits. Too low can mean the grid has failed.

Safe to reset?
Safe to restart
When to call an engineer
Check the house has power. If W004 is frequent, raise it with your DNO.

W006, W007Grid frequency too high or too low

The grid frequency is outside the set limits. Common on generator supplies.

Safe to reset?
Safe to restart
When to call an engineer
If you run a generator, check its output frequency.

W010Fan fail

The internal fan has failed, so the inverter will eventually overheat.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer. Replacement is likely.

W015Anti-islanding disconnection

The inverter lost the grid or is incorrectly connected.

Safe to reset?
Check first
When to call an engineer
Check the solar breaker and AC isolator. If both are on, call an engineer.

W046Grid connection unsuccessful

The inverter could not complete its connection to the grid.

Safe to reset?
Check first
When to call an engineer
Restart once at the isolators. If it repeats, call us.

Errors (E codes)

E codes usually point to a fault inside the inverter. On units of this age, replacement is often better value than repair.

E001Input over-current

Current from the panels is above the inverter’s maximum.

Safe to reset?
Check first
When to call an engineer
Call us if it repeats.

E002Input over-voltage

Voltage from the panels is above the maximum. The inverter will not start while it is active.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Switch off the DC isolator and call an engineer.

E004Bulk over-voltage

An internal DC fault, usually a sign of failure.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer; the inverter will likely need replacing.

E005Internal communication error

Parts of the inverter have stopped communicating.

Safe to reset?
Check first
When to call an engineer
Restart once. If it persists, replacement is likely.

E006Output over-current

Output current went above the maximum.

Safe to reset?
Safe to restart
When to call an engineer
Restart. Call us if it repeats.

E009Internal error

An internal failure, possibly a corrupted processor.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer; replacement is likely.

E031Output relay fault

The relay that connects the inverter to the grid has failed. Common on older units, which often start failing at around seven years old.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call us. We recommend replacing the inverter rather than repairing the relay.

Written in our own words from the manufacturer’s documentation. For the full list, see FIMER (formerly ABB solar).

Power-One questions

What does W003 mean on an Aurora inverter?

The grid voltage or frequency is outside the limits set at installation, so the inverter has disconnected. It reconnects when the grid returns to range. Frequent W003s are worth raising with your DNO.

What does E031 mean on a Power-One inverter?

The internal relay that connects the inverter to the grid has failed. It is a common fault on older units, and replacement is usually better value than repair.

Is it worth repairing an old Aurora Power-One inverter?

Usually not. For most faults inside an older Aurora we recommend a modern replacement, which can also be made ready for a battery.

Get a free solar quote

Need a new inverter, a battery or a full upgrade? Tell us about your home. For a Power-One fault, use Report a fault instead.