Growatt inverter error codes

Growatt inverters show either a message, such as No AC Connection, or a numbered error, such as Error 117, on the screen and in the ShinePhone app. The first safe check is whether the house has power and the solar breaker in your fuse box is on.

By Scott Charles, Bolido Solar
Updated

Messages

No AC ConnectionNo grid

The inverter cannot see the grid, usually because of a power cut or a switched-off breaker or isolator.

Safe to reset?
Check first
When to call an engineer
Check the solar breaker and AC isolator. If both are on and the fault stays, call an engineer.

AC V OutrangeGrid voltage out of range

The grid voltage is outside the permitted range. It can happen in summer when a lot of solar feeds the grid.

Safe to reset?
Safe to restart
When to call an engineer
If it persists, ask your DNO to check the supply, then call us.

AC F OutrangeGrid frequency out of range

The grid frequency is outside the permitted range.

Safe to reset?
Safe to restart
When to call an engineer
Call us if it persists.

PV Isolation LowInsulation problem

A leak to earth on the panel side, which may mean an earth fault on the roof.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Book an engineer to test the array.

Residual I HighLeakage current too high

Current is leaking to earth.

Safe to reset?
Check first
When to call an engineer
Restart once at the isolators. If it returns, call an engineer.

Output High DCIDC offset on the output

Too much DC on the AC output current.

Safe to reset?
Check first
When to call an engineer
Restart once. If it returns, call an engineer.

PV Voltage HighDC input voltage too high

The voltage from the panels is above the maximum the inverter can tolerate.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Switch off the DC isolator straight away and call an engineer.

Over TemperatureTemperature out of range

The inverter is too hot.

Safe to reset?
Check first
When to call an engineer
Make sure it is not covered or boxed in. Restart once; call if it returns.

Auto Test FailedSelf-test failed

The inverter failed its automatic self-test.

Safe to reset?
Safe to restart
When to call an engineer
A restart usually clears it. Call us if it does not.

Numbered errors

Numbered errors usually point to a fault inside the inverter. A restart is worth one try; if the error returns, it needs an engineer.

Error 101, 121Internal communication fault

The inverter’s two processors are not exchanging data.

Safe to reset?
Check first
When to call an engineer
Turn off the DC isolator, let the inverter shut down fully, then turn it back on. Call if it persists.

Error 102Consistency fault

The two processors disagree about what they are measuring.

Safe to reset?
Check first
When to call an engineer
Restart as for Error 101. Call if it persists.

Error 116EEPROM fault

The inverter cannot read or write its internal memory.

Safe to reset?
Check first
When to call an engineer
If it appears all day after a restart, the control board needs replacing. Call us.

Error 117Relay fault

Something is wrong with the relay circuit that connects the inverter to the grid.

Safe to reset?
Check first
When to call an engineer
Restart once. If it returns, call an engineer.

Error 119GFCI device fault

The internal earth-leakage detection device may be damaged.

Safe to reset?
Check first
When to call an engineer
Restart two or three times. If it stays, call an engineer.

Error 120Current sensor fault

A problem with an internal current sensor.

Safe to reset?
Check first
When to call an engineer
Restart once. If it returns, call an engineer.

Error 122Bus voltage fault

The internal DC voltage is out of range.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer.

Written in our own words from the manufacturer’s documentation. For the full list, see Growatt support and manuals.

Growatt questions

What does Growatt Error 117 mean?

A relay fault: the circuit that connects the inverter to the grid is not working properly. Restart it once at the isolators; if the error comes back, it needs an engineer.

What does PV Isolation Low mean on a Growatt?

An insulation problem on the panel side, often an earth fault on the roof from water in a connector or a damaged cable. Book an engineer to test the array.

What does No AC Connection mean on a Growatt?

The inverter cannot see the grid. Check for a power cut, then the solar breaker and AC isolator. If all are fine and the message stays, call an engineer.