Solar panels not working? Safe checks before you call anyone

Most solar faults show up in one of three places: the inverter display, the fuse box or the monitoring app. This guide from Bolido Solar takes you through the checks a homeowner can do safely, in order, and tells you when to stop and call an engineer.

By Scott Charles, Bolido Solar
Updated

Six checks, in order

  1. 01

    Is there enough daylight?

    Output falls to nothing at night and drops sharply on dark winter days. Check again around midday on a bright day before deciding something is wrong.

  2. 02

    Read the inverter

    Look at its display or lights. Green usually means normal, red or orange means a fault. Write down any code exactly as shown and look it up in our error code library.

  3. 03

    Check the fuse box

    Find the breaker or RCD labelled for the solar in your consumer unit. If it has tripped, reset it once. If it trips again, leave it off and call: repeated trips point to a fault such as water in a connector.

  4. 04

    Check both isolators

    The AC isolator is a switch near the inverter or the fuse box; the DC isolator sits beside the inverter. Both should be on. They sometimes get switched off during other work in the house.

  5. 05

    Compare the monitoring with the display

    If the inverter shows power being made but the app shows nothing, the system is probably fine and the monitoring has lost its internet link. A new router or Wi-Fi password is the usual cause.

  6. 06

    Look at the array from the ground

    New shading from trees or scaffolding, cracked or slipped panels, cables hanging loose, or birds going in and out under the panels are all worth a photo.

What the symptoms usually mean

A rough guide to where the fault is likely to be, so you know who to call.

  • Nothing on the inverter display on a bright day: no AC supply reaching it, or a failed inverter
  • Inverter on but showing a grid fault: a problem on the network side, so check with your DNO, the company that runs your local power network
  • Inverter normal but generation low: shading, one string of panels down, or ageing connectors
  • An RCD that trips in wet weather: an insulation fault, usually water getting into a connector
  • Monitoring blank while the inverter is working: a network or Wi-Fi problem, not a solar one

When to call an engineer

Call when the same fault comes back after a restart, when an RCD trips more than once, when generation is well down on the same month last year, or straight away if you smell burning or see damage. A photo of the inverter screen and the fuse box saves time on the visit.

Troubleshooting questions

Why have my solar panels stopped working?

The most common causes are a tripped breaker or RCD, an isolator switched off, a failed inverter or a grid fault. Work through the six checks above; the inverter display usually tells you which.

Why does my solar trip the RCD when it rains?

Almost always an insulation fault: water getting into a cable or connector and leaking to earth. It gets worse over time, so leave the RCD off after a second trip and book an engineer.

Is it safe to switch my inverter off and on again?

Yes, using the AC and DC isolators, which are designed to be switched by hand. Follow the order in your inverter manual. If the fault returns after a restart, leave it and call.

Why is my solar making less than last year?

New shading, dirt or birds on the panels, a string that has stopped working, or a slowly failing inverter. Compare the same month year on year; a big drop is worth a maintenance visit.

Get a free solar quote

Thinking about a battery, an upgrade or a new system once it's fixed? Tell us about your home and we'll call you back.

or call 0330 345 3400